 PRELIMINARY DATA SHEET
MOS INTEGRATED CIRCUIT
PD168111
MICROSTEP DRIVER FOR DRIVING CAMERA LENS
DESCRIPTION
The PD168111 is a monolithic 2-channel H bridge driver that consists of a CMOS controller and a MOS output stage. It can reduce the current consumption and the voltage loss at the output stage compared with a conventional driver using bipolar transistors, thanks to employment of a MOS process. consumption can be substantially reduced during operation. This product is ideal for driving the motor of a digital still camera as it can switch over between two-phase excitation driving and microstep driving, using a stepper motor. This product employs a P-channel As a result, the circuit current MOSFET on the high side of the output stage, eliminating a charge pump.
FEATURES
O Two H bridge circuits employing power MOSFET O Current feedback 64-step microstep driving and two-phase excitation driving selectable O Motor control by serial data (6 words of 16-bit configuration) Data is input with the LSB first. Pulse cycle, number of pulses, and output current value can be set. O Input logic frequency: 6 MHz MAX. O 3 V power supply Minimum operating power supply voltage VDD = 2.7 V O Undervoltage lockout circuit Shuts down internal circuitry at VDD = 1.7 V TYP. O 24-pin TSSOP
ORDERING INFORMATION
Part Number PD168111MA-6A5 Package 24-pin plastic TSSOP (5.72 mm (225))
The information in this document is subject to change without notice. Before using this document, please confirm that this is the latest version.
Not all products and/or types are available in every country. Please check with an NEC Electronics sales representative for availability and additional information.
Document No. S15865EJ1V0DS00 (1st edition) Date Published March 2003 N CP(K) Printed in Japan
(c)
PD168111
PIN FUNCTIONS
Package: 24-pin TSSOP
SCLK SDATA MOB LGND COSC PGND2 OUT2B VM2 OUT2A FB2 EXT0 EXT1
1 2 3 4 5 6 7 8 9 10 11 12
24 23 22 21 20 19 18 17 16 15 14 13
LATCH OSCIN FIL2 VDD FIL1 FB1 OUT1B VM1 OUT1A PGND1 EN RESETB
Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Pin Name SCLK SDATA MOB LGND COSC PGND2 OUT2B VM2 OUT2A FB2 EXT0 EXT1 RESETB EN PGND1 OUT1A VM1 OUT1B FB1 FIL1 VDD FIL2 OSCIN LATCH Serial clock input pin Serial data input pin
Pin Function
Phase detection output pin Control block GND pin Pin connecting capacitor for output oscillator Output block GND pin Channel 2 output B Motor power pin Channel 2 output A Channel 2 current detection resistor connecting pin Logic block monitor output pin 1 Logic block monitor output pin 2 Reset input pin Output enable pin Output block GND pin Channel 1 output A Motor power pin Channel 1 output B Channel 1 current detection resistor connecting pin Channel 1 filter capacitor connecting pin Control block power pin Channel 2 filter capacitor connecting pin Original oscillation clock input pin Serial data latch input pin
2
Data Sheet S15865EJ1V0DS
PD168111
BLOCK DIAGRAM
OSCIN 23 RESETB VDD VM1 VM2 13 21 SERIAL-PARALLEL DECODER 17 8 1/N PULSE GENERATOR EXTOUT SELECTOR 11 12 3 FILTER -+ FILTER EXT0 EXT1 MOB SCLK 1 SDATA 2 LATCH 24
EVR1 COSC LGND 5 4 OSC +
EVR2
CURRENT SET
Internal Block VM H BRIDGE ch1 20 FIL1 14 EN 22 FIL2 9 7 6 PGND2 Current Sense2 10 FB2
FB1
Current 19 Sense1
VM
H BRIDGE ch1 15 PGND1 16 18
OUT1A OUT1B
OUT2A OUT2B
Data Sheet S15865EJ1V0DS
3
PD168111
EXAMPLE OF STANDARD CONNECTION
CPU
OSCIN
SCLK
SDATA LATCH
RESETB VDD VM1 3.3 V VM2 5V COSC 330pF LGND Current Sense1 VM H BRIDGE ch1 FILTER FILTER VM H BRIDGE ch2 OSC 1/N PULSE GENERATOR EVR1 EVR2 CURRENT SET EXTOUT SELECTOR EXT0 EXT1 MOB 100 k VDD SERIAL-PARALLEL DECODER
Internal Block
FB1 2 k Note 1 1000 pF Note 2
Current Sense2
FB2 2 k Note 1 1000 pF Note 2
PGND
OUT1A OUT1B
FIL1
EN
FIL2
OUT2A OUT2B
PGND
1000 pF 1000 pF Note 3 from CPU Note 3 M
This circuit diagram is shown as an example and is not intended for mass production. Connect a bypass capacitor between the power supply and GND pins for stabilization. Notes 1. Adjust the value of the external resistor according to the output current. The relationship between the output current and external resistance is as follows. Output current IOUT EVRMAX / FB x 1000 2. It is recommended to connect a capacitor to the FB pin for stabilization to suppress the electronic noise superimposed on the pin. 3. The capacitor connected to the FIL pin is used to suppress the voltage noise for stabilization. Adjust the capacitance of the capacitor to effectively suppress the noise.
4
Data Sheet S15865EJ1V0DS
PD168111
COMMAND INPUT TIMING CHART
This IC controls the motor by transmitting serial control commands. Here is an example of the commands.
Internal reset cleared RESET
LATCH
SCLK
SDATA External reference CLK Start point wait Start point excitation wait Pulse output EXT0
;;;; ; ;; ; ;;;;;;;;;;;; ;;;; ; ;; ;
Dummy data D0 D1 D2 D3 16 bit Initialization setting (wait value setting) Pulse setting, etc. Pulse setting, etc. Pulse setting, etc. All `0' Output depending on initialization setting Output depending on initialization setting
Synchronized with pulse timing according to setting of D1 Synchronized with pulse timing according to setting of D2 Driving period H set by D2 Driving period H set by D1
Pulse output EXT1
This IC can change all commands by issuing the LATCH signal once. Therefore, "initialization setting" does not have to be explicitly performed as shown in the above example. Immediately after the reset has been cleared, dummy data must be transmitted according to the timing of the transmit data. For details, refer to SERIAL INTERFACE SPECIFICATIONS.
Data Sheet S15865EJ1V0DS
5
PD168111
OUTPUT TIMING CHART
* Microstep output mode
RESET position Ch1 current
100 99.5 98.1 95.7 92.4 88.2 83.1 77.3 70.7 63.4 55.6 47.1 38.3 29.0 19.5 9.8 0 --9.8 --19.5 --29.0 --38.3 --47.1 --55.6 --63.4 --70.7 --77.3 --83.1 --88.2 --92.4 --98.1 --95.7 --99.5 --100
0
100 99.5 98.1 95.7 92.4 88.2 83.1 77.3 70.7 63.4 55.6 47.1 38.3 29.0 19.5 9.8 0 --9.8 --19.5 --29.0 --38.3 --47.1 --55.6 --63.4 --70.7 --77.3 --83.1 --88.2 --92.4 --98.1 --95.7 --99.5 --100
5
10
15
20
25
30
35
40
45
50
55
60
65
Ch2 current
0
5
10
15
20
25
30
35
40
45
50
55
60
65
MOB output: (Da of 1-phase excitation position address 2 = "1", Db = "0")
0
5
10
15
20
25
30
35
40
45
50
55
60
65
MOB output: (Da of 2-phase excitation position address 2 = "1", Db = "0")
0
7
23
39
55
The horizontal axis indicates the number of steps. The pulse advances in synchronization with the rising edge of CLK. The current flows into ch1 and ch2 in the positive direction when it flows from OUT1A to OUT1B, and in the negative direction when it flows from OUT1B to OUT1A (the values shown above are ideal values and do not indicate the actual values).
6
Data Sheet S15865EJ1V0DS
PD168111
OUTPUT TIMING CHART
* 2-phase excitation output mode
Ch1 current
100%
-100% 0 1 2 3 4 Ch2 current 5 6 7 8
100%
100% 0 1 2 3 4 5 6 7 8
MOB output
0
1
2
3
4
5
6
7
8
The horizontal axis indicates the number of steps. This figure shows an example in the CW mode. The current flows into ch1 and ch2 in the positive direction when it flows from OUT1A to OUT1B, and in the negative direction when it flows from OUT1B to OUT1A.
Data Sheet S15865EJ1V0DS
7
PD168111
Relationship Between Revolution Angle, Phase Current, and Vector Amount (64 microsteps)
Revolution Angle 0 5.625 11.250 16.875 22.500 28.125 33.750 39.375 45 50.625 56.250 61.875 67.500 73.125 78.750 84.375 90 Phase A - Phase Current MIN. - 2.5 12.4 22.1 31.3 40.1 48.6 58.4 65.7 72.3 78.1 83.2 87.4 90.7 93.2 94.5 - TYP. 0 9.8 19.5 29.0 38.3 47.1 55.6 63.4 70.7 77.3 83.1 88.2 92.4 95.7 98.1 100 100 MAX. 3.8 17.0 26.5 36.1 45.3 54.1 62.6 68.4 75.7 82.3 88.1 93.4 97.4 100.7 103.0 104.5 - Phase B - Phase Current MIN. - 94.5 93.2 90.7 87.4 83.2 78.1 72.3 65.7 58.4 48.6 40.1 31.3 22.1 12.4 2.5 - TYP. 100 100 98.1 95.7 92.4 88.2 83.1 77.3 70.7 63.4 55.6 47.1 38.3 29.0 19.5 9.8 0 MAX. - 104.5 103.0 100.7 97.4 93.2 88.1 82.3 75.7 68.4 62.6 54.1 45.3 36.1 26.5 17.0 3.8 Vector Amount TYP. 100 100.48 100 100.02 100.02 99.99 99.98 99.97 99.98 99.97 99.98 99.99 100.02 100.02 100 100.48 100
Step
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
The above values are ideal values and do not indicate the actual values.
8
Data Sheet S15865EJ1V0DS
PD168111
FUNCTION DESCRIPTION
2-phase excitation driving mode By allowing a current of 100% to flow into output ch1 and ch2 at the same time, a motor can be driven with the larger torque. The motor can also be driven on a constant current to reduce the power consumption. The two-phase driving mode and microstep driving mode are selected by a command. Microstep driving of stepper motor To position a stepper motor with high accuracy, the PD168111 has a function to hold constant the current flowing through the H bridge by a vector value and to stop one cycle in 64 steps. A 16-bit serial interface is used for controlling, so that the motor can be directly controlled by the CPU while mitigating the load of the CPU. To realize the microstep driving mode, the driver internally realizes the following functions. * Detecting the current flowing into each channel as a voltage value by a sense resistor * Synthesizing the dummy sine wave of the half-wave generated by the internal D/A and PWM oscillation wave for chopping operation * The driver stage performs PWM driving based on the result of comparing the detected voltage value and synthesized waves. The internal dummy sine wave is of 64 steps per cycle, so that the stepper motor can be driven in 64 steps. The microstep driving mode and two-phase excitation driving mode are switched by a command.
+
M A
Concept of microstep driving operation
Serial control Information necessary for microstep driving is processed by serial data from the CPU. The commands that specify the following parameters can be set. * Start point wait and start point excitation wait * Chopping frequency * Motor current, motor revolution direction, and output excitation mode * Acceleration/deceleration circuit parameters * Pulse cycle, number of pulses, and pulse number multiplication factor An address is allocated to each command. Each data can be updated by inputting 16-bit data. For the configuration of the data and details of the commands, refer to SERIAL INTERFACE SPECIFICATIONS. A command is specified by specifying an address. Only the data that must be updated can be input. The previous data of the address for which no data is input is retained.
Data Sheet S15865EJ1V0DS
9
PD168111
Reset function (RESET pin) To initialize the internal registers of this IC, be sure to perform a reset operation after power application. The registers are initialized and all the internal data are cleared to "0" when the RESETB pin is "L". The internal circuitry is stopped. The current consumption is reduced to 1 A MAX. by stopping the external CLK input. The output goes into a Hi-Z state. When the RESETB pin is "H", excitation can be started from the initial excitation position with the current of ch1 at +100% and the current of ch 2 at 0% (one-phase excitation position). To perform two-phase excitation driving, the initial excitation position is in the status where the currents of ch1 and ch2 are +100% after the command has been set. After the RESETB pin has gone "H", the MOB pin outputs "L" until the pulse is output. Output enable function (EN pin) This IC generates the pulse output timing by setting a start point wait and start point excitation wait, and outputs pulses. The output enable function (EN pin) allows an external source to forcibly stop the pulse output. When the EN pin goes "L", the output is forcibly made to go into a Hi-Z state. Then the device enters the standby mode described below. Be sure to input a command while the EN pin is "H". If pulse output continues when the EN pin is "L", pulse output is started from the excitation status when the EN pin goes "H" once and then "L" again. Standby function The PD168111 can be set in the standby mode by making the EN pin "L". In this mode, as many internal circuits as possible are stopped, so that the self current consumption can be reduced. By stopping input of the external CLK, the current consumption can be reduced to 30 A MAX. It is 300 A MAX. when the external CLK is input. In the standby mode, the contents of the internal registers and motor excitation position information are retained. After the standby mode is released, therefore, driving the motor can be started without having to perform an initialization operation. To release the standby mode, input the external CLK and make the EN pin "H".
10
Data Sheet S15865EJ1V0DS
PD168111
The device is set in and released from the standby mode as follows. (1) Setting device in standby mode External CLK off EN pin "L" When the external CLK is turned off, the internal logic circuit is stopped. Because the output stage operates, however, excitation continues. If the EN pin is made "L", excitation is turned off and the device is set in the standby mode. EN pin "L" external CLK off When the EN pin goes "L", excitation is turned off and the device enters the standby mode (300 A MAX.). When the external CLK is later turned off, the current consumption decreases to 30 A MAX. (2) Releasing device from standby mode External CLK on EN pin "H" When the external CLK is input, the standby mode continues and the current consumption increases to 300 A. When the EN pin goes "H", excitation is enabled. EN pin "H" external CLK on When the EN pin goes "H", excitation is enabled. Because the external CLK is turned off, however, the pulse is not output but excitation continues. When the external CLK is input later, the pulse can be output.
Data Sheet S15865EJ1V0DS
11
PD168111
Acceleration/deceleration circuit This IC can control the acceleration/deceleration output pattern of a stepper motor by commands. By performing an acceleration/deceleration operation, step out of the stepper motor due to torque insufficiency can be prevented, and stable open loop control can be performed. For the details of the acceleration/deceleration operation parameters, refer to SERIAL INTERFACE SPECIFICATIONS. MOB output The MOB pin outputs a signal as specified by a command. By monitoring the MOB output, the excitation position of the stepper motor can be checked. In microstep output mode, the MOB pin outputs "L" when In microstep output mode, the MOB pin outputs "L" when "the current of ch 1 or ch 2 is 100%" (four pulses are output per cycle), or "the current of ch 1 is +100%) (one pulse is output per period) as the one-phase excitation position, or "the current of ch 1 or ch 2 is 70%" (four pulses are output per cycle), or "the current of ch 1 is +70%) (one pulse is output per cycle) as the two-phase excitation position. In the two-phase excitation output mode, the MOB pin outputs "L" when "the currents of ch 1 and ch 2 are positive and the same value". The MOB output indicates the stop position information of the stop mode to be described below. The MOB output goes into a Hi-Z state when the RESETB pin is "L" and EN pin is "L" (standby mode). When D7 of address 2 = 0 (output disabled), the MOB pin outputs a signal in accordance with the stop position. Stop mode When the stop mode is set by a command, pulses are automatically output until the MOB pin goes "L". The device operates regardless of the set number of pulses and it no longer outputs pulses in the stop mode when the MOB pin goes "L". The output retains the excitation status. To advance the pulse again, release the stop mode and restore the normal mode by a command. After the stop mode has been set, note that the stop position of the motor does not match the set number of pulses.
12
Data Sheet S15865EJ1V0DS
PD168111
Excitation position immediately after reset The initial excitation position immediately after reset is where the current of ch1 is +100% and the current of ch2 is 0%. The following table summarizes the operations from the initial position at each command setting.
RESETB = "L" "H" Operation Mode to Start Point Wait End Output Hi-Z state 1 CCW mode 2-phase excitation CW mode 2 CCW mode
ch1 CCW + CW
Start Point Wait End to Start Point Excitation Wait End
Excitation Stop Position with 0 Pulse Set 1
Excitation Stop Position with 1 Pulse Set 5 6 3
Microstep
CW mode
2 4
1 RESETB 4
6
5
2
LATCH
Start point wait Start point excitation wait
-
+
ch2
3
-
Undervoltage lockout circuit (ULVO) This circuit forcibly stops the operation of this IC to prevent malfunction of the circuitry when the VDD voltage of the IC abruptly drops. This function may not operate when the VDD voltage abruptly drops in the order of s. Power application sequence This IC has two power supply pins: logic power supply (VDD) and output power supply (VM). To turn on power, turn on VM with VDD turned on. To turn off power, turn off VM with VDD turned on, and then turn off VDD. (VDD and VM can also be turned on/off at the same time.)
Data Sheet S15865EJ1V0DS
13
PD168111
SERIAL INTERFACE SPECIFICATIONS
The internal data is determined by inputting 16-bit serial data SDATA synchronized with serial clock SCLK and making LATCH "L". The serial data is input from the LSB (D0) to the MSB (Df). SDATA: Data is loaded to the internal circuitry in synchronization with the rising of SCLK when LATCH = "H". LATCH: Inputting SDATA is prohibited when LATCH is "L". Inputting is enabled when it is "H". The internal data is determined at the negative transition of LATCH (from "H" to "L"). Because this IC generates the internal timing via the external CLK (OSCIN) its set values depend upon the frequency of OSCIN. An example where OSCIN = 5 MHz is given below. To input a frequency other than 5 MHz to OSCIN, use the following expression. Items related to the serial register are marked Time: Set value = Setting example x (5/OSCIN [MHz]) Frequency: Set value = Setting example x (OSCIN [MHz]/5) Data configuration 16-bit data consists of 3 address bits and 13 data bits. Three bits (Dd, De, and Df) are used to set an address. Five types of addresses, 0 to 5, can be used. Thirteen bits (D0 to Dc) are used to set data.
bit Data Df Address De Dd Dc Data Db Da D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
.
Example Address 1: (Df, De, Dd) = (0, 0, 1) Address 3: (Df, De, Dd) = (0, 1, 1) For how to set data, refer to Serial Register List and Serial Register Details. The following chart shows an example of the serial command waveform.
0 SCLK 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
SDATA
LATCH
14
Data Sheet S15865EJ1V0DS
PD168111
NOTES ON TRANSMITTING DATA
* Basically, the input data is loaded when SCLK changes from "L" to "H" after LATCH has changed from "L" to "H". Data is transmitted in 16-bit units, and is determined when LATCH changes from "H" to "L". Invalid data of less than 16 bits is discarded. * Data of different addresses can be input successively while LATCH = "H". * The access time can be shortened by updating only the necessary data after initialization has been performed. If an address is not input, the previous value of that address is retained as the data. * If the same address is input more than once while LATCH is "H", the data that is input last is valid. * If invalid data and correct data are input while LATCH is "H", only the correct data is valid. * If only LATCH is input, the data is not updated, and the driver holds the current status. * Data that is transmitted during the start point wait and start point excitation wait periods is ignored. * Data that is transmitted when the RESETB pin is "L" and the EN pin is "L" is ignored. * As shown below, dummy data must be transmitted immediately after reset if SCLK = "H" while LATCH = "L".
LATCH
SCLK
SDATA
The dummy data is defined to be "data of all 0 at address 0". Transmit the dummy data before transmitting the correct data. This operation is necessary only immediately after reset. Once the dummy data has been transmitted, it does not have to be transmitted again until the next reset operation is performed or the power is turned off and then back on again. If SCLK = "L" while LATCH = "L", the dummy data does not have to be transmitted immediately after reset. However, there is no problem even if the dummy data is transmitted.
Data Sheet S15865EJ1V0DS
15
PD168111
Address List
Address Address 0 Address 1 Address 2 Address 3 Address 4 Address 5 Item to Be Set Start point wait, start point excitation wait Chopping frequency Motor drive initialization, motor current Acceleration/deceleration parameter, pulse number multiplication factor Pulse cycle Number of pulses
Table. Serial Register List (1/2)
Bit f e d c b a 9 8 7 6 5 4 3 2 1 0 (Reserve) Start point excitation wait 5 Start point excitation wait 4 Start point excitation wait 3 Start point excitation wait 2 Start point excitation wait 1 Start point excitation wait 0 Start point wait 5 Start point wait 4 Start point wait 3 Start point wait 2 Start point wait 1 Start point wait 0 Address 0 0 0 Address 0 (000) Bit f e d c b a 9 8 7 6 5 4 3 2 1 0 (Reserve) (Reserve) (Reserve) (Reserve) (Reserve) (Reserve) Pulse output function selection during EXT output Chopping frequency 5 Chopping frequency 4 Chopping frequency 3 Chopping frequency 2 Chopping frequency 1 Chopping frequency 0 Address 0 0 1 Address 1 (001)
16
Data Sheet S15865EJ1V0DS
PD168111
Table. Serial Register List (2/2)
Bit f e d c b a 9 8 7 6 5 4 3 2 1 0 (Reserve) MOB output position setting (for microstep driving only) MOB output selection setting (for microstep driving only) 2-phase excitation current selection 2-phase excitation/microstep driving selection Output enable setting Stop mode setting Revolution direction setting (CW/CCW) Motor current setting during normal operation 4 Motor current setting during normal operation 3 Motor current setting during normal operation 2 Motor current setting during normal operation 1 Motor current setting during normal operation 0 Address Address 2 (010) 0 1 0 Bit f e d c b a 9 8 7 6 5 4 3 2 1 0 (Reserve) (Reserve) Acceleration enabled/disabled Deceleration enabled/disabled For acceleration/deceleration control For acceleration/deceleration control For acceleration/deceleration control For acceleration/deceleration control For acceleration/deceleration control For acceleration/deceleration control For acceleration/deceleration control Motor pulse multiplication factor setting 1 Motor pulse multiplication factor setting 0 Address Address 3 (011) 0 1 1
Bit f e d c b a 9 8 7 6 5 4 3 2 1 0 Address
Address 4 (010) 1 0 0 Motor pulse cycle setting 12 Motor pulse cycle setting 11 Motor pulse cycle setting 10 Motor pulse cycle setting 9 Motor pulse cycle setting 8 Motor pulse cycle setting 7 Motor pulse cycle setting 6 Motor pulse cycle setting 5 Motor pulse cycle setting 4 Motor pulse cycle setting 3 Motor pulse cycle setting 2 Motor pulse cycle setting 1 Motor pulse cycle setting 0
Bit f e d c b a 9 8 7 6 5 4 3 2 1 0 Address
Address 5 (011) 1 0 1 Motor pulse setting number 12 Motor pulse setting number 11 Motor pulse setting number 10 Motor pulse setting number 9 Motor pulse setting number 8 Motor pulse setting number 7 Motor pulse setting number 6 Motor pulse setting number 5 Motor pulse setting number 4 Motor pulse setting number 3 Motor pulse setting number 2 Motor pulse setting number 1 Motor pulse setting number 0
Data Sheet S15865EJ1V0DS
17
PD168111
SERIAL REGISTER DETAILS Address 0
This register is used to set a start point wait and start point excitation wait. The data must not both be set to "0".
MSB bit Data Df 0 De 0 Dd 0 Dc - Db Da D9 D8 D7 LSB D6 MSB D5 D4 D3 D2 D1 LSB D0
Start point excitation wait
Start point wait
* Start point wait Counting is started from the falling of the LATCH signal, and the motor is excited when the count value has reached 0. Data D0 to D5 can be used to set a count value of 32 to 2016 s at a resolution of 32 s. * Start point excitation wait Counting is started after counting of the start point wait has been completed, and the output pulse is generated when the count value has reached 0. Data D6 to Db can be used to set a count value of 32 to 2016 s at a resolution of 32 s.
LATCH
Start point wait Driving mode updating point Start point excitation wait Driving mode updating point
EN pin
Pulse output Data loaded & Data updated. wait count Output turned on started (if turned on from output Hi-Z status)
Pulse output Pulse output Pulse output stopped & started standby mode set
Pulse output based on the previous data continues even during the start point wait and start point excitation wait periods. The updated data is reflected and the pulse is output after completion of the start point excitation wait.
18
Data Sheet S15865EJ1V0DS
PD168111
Example of setting start point wait and start point excitation wait D5 ... D0 and Db ... D6 000000 000001 000010 : 111101 111110 111111 Set Value (s) Prohibited 32 64 : 1952 1984 2016
Caution "000000" cannot be set but the default value immediately after reset is "000000". This default value is used only for dummy data. Be sure to set a value other than "000000".
Data Sheet S15865EJ1V0DS
19
PD168111
Address 1 This register is used to set a chopping frequency that is the basis of PWM output. This register is also used to test the internal circuitry of the IC.
MSB bit Data Df 0 De 0 Dd 1 Dc Db Da D9 D8 D7 D6 Note D5 D4 D3 D2 D1 LSB D0
Test function
Chopping frequency
Note Pulse output function selection during EXT output * Chopping frequency A chopping method is employed for the output to drive the motor on a constant current. The chopping frequency that is the basis of the output can be changed with data, so that the PWM output does not interfere with the other signals. The chopping frequency can be set in a range of 40 to 250 kHz by the data D0 to D5. Refer to the following table for the set value. Chopping Frequency (kHz) 0 (no pulse output) 0 (no pulse output) : 0 (no pulse output) 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 Chopping Frequency (kHz) 120 125 130 140 145 Chopping Frequency (kHz)
D5......D0 000000 000001 : 000111 001000 001001 001010 001011 001100 001101 001110 001111 010000 010001 010010 010011 010100 010101 010110 010111
D5......D0 011000 011001 011010 011011 011100 011101 011110 011111 100000 100001 100010 100011 100100 100101 100110 100111 101000 101001 101010 101011
D5......D0 101100 101101 101110 101111 110000 110001 110010 110011 110100 110101 110110 110111
225
155
165
180
111000 111001 111010
250
190
111011 111100 111101
210
111110 111111
20
Data Sheet S15865EJ1V0DS
PD168111
* Pulse output function selection during EXT output D6 is used to select a function to monitor the output of the driving pulse by using the EXT pins. When D6 = 0, the EXT pins (EXT0 and EXT1) are fixed to "L" (output the necessary level when the test function is enabled). When D6 = 1, EXT0 is in the output pulse synchronization mode and EXT1 is fixed to "H" during output. The duty factor of EXT0 output is 50% (TYP.), in accordance with the set pulse cycle. To count the number of pulses, count the rising edges of EXT0. Note that EXT0 and EXT1 have the following restrictions. * EXT0 output restrictions (1) EXT0 output is not guaranteed when the pulse cycle is 1 s (Dc to D0: 0000000000001). (2) EXT0 outputs a level equivalent to the H level time for normal driving (equivalent to the set pulse cycle) while an acceleration/deceleration operation is being performed. (3) If the pulse number multiplication factor is set to a value other than "1", EXT0 outputs a level for the duration equivalent to the set number of pulses (address 5xm). * EXT1 output restriction (1) EXT1 falls in synchronization with the falling of EXT0 at the same timing. When the last pulse is output, therefore, it rises earlier than the period of the pulse cycle (50% of pulse cycle or less).
Internal pulse output
During acceleration
During deceleration Acceleration Deceleration
Operation Mode D6 EXT0 0 1 EXT1 Not output (in accordance with test function) Output pulse synchronization mode Output period fixed to "H" mode
Test function The test function is used to check the internal operations of the IC. Input "0" as data D7 to Dc.
Data Sheet S15865EJ1V0DS
21
PD168111
Address 2 This register is used to set the maximum current value for constant-current driving, the revolution direction of the motor (CW/CCW), and the operation mode.
bit Data Df 0 De 1 Dd 0 Dc Db Da D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
(Reserve) Note 7 Note 6 Note 5 Note 4 Note 3 Note 2 Note 1 Output current
Notes 1. Motor revolution direction 2. Stop mode 3. Output enable setting 4. 2-phase excitation/microstep driving selection 5. 2-phase excitation current selection 6. MOB output selection setting (only during microstep driving) 7. MOB output position setting (only during microstep driving) * Setting of output current An internal reference voltage value (EVRMAX) for constant-current driving is set. The internal reference voltage is specified by data D0 to D4 at a resolution of 20 mV. Microstep driving can be performed with the set reference voltage as the maximum value. The ideal peak value of the drive current is EVRMAX (V)/Rsense () x 1000. Set value EVRMAX = (D4 ... D0) x 20 mV where, 100 mV EVRMAX 500 mV
D4......D0 00000 00001 : 00101 00110 00111 : Reference Voltage (mV) 100 100 : 100 120 140 : D4......D0 10110 10111 11000 11001 : 11110 11111 Reference Voltage (mV) 440 460 480 500 : 500 500
If a voltage less than 100 mV is set, the reference voltage is set to 100 mV. If a voltage higher than 500 mV is set, it is set to 500 mV. * Motor revolution direction setting D5 is used to specify the motor revolution direction. In the CW mode, the current of ch2 is output, 90 degrees in phase behind the current of ch1. In the CCW mode, the current of ch2 is output, 90 degrees in phase ahead of the current of ch.
D5 0 1 Operation Mode CW mode (forward revolution) CCW mode (reverse revolution)
22
Data Sheet S15865EJ1V0DS
PD168111
* Stop mode setting When D6 = "1", the motor advances to the position of MOB output = "L", and the output status is held. The set number of pulses is held even in the stop mode. Because the motor is driven regardless of the set number of pulses, however, the position information of the motor must be taken into consideration when a command is set to resume driving.
D6 0 1 Operation Mode Normal mode Stop mode
Caution Inputting data is prohibited while the stop mode is set (until MOB = "L"). Do not update the data. No pulse is output if the stop mode is set while MOB = "L". * Output enable setting When D7 = "1", the motor can be driven. To drive the motor, be sure to set this bit to "1". When D7 = "0", the output goes into a Hi-Z state, regardless of the other settings. Unlike the EN pin that is controlled by an external source, the standby status is not set even when D7 = "0". If D7 is changed from "0" to "1", the internal information is held and therefore the excitation position is recorded. Therefore, excitation is started from the position where D7 is cleared to "0".
D7 0 1 Operation Mode Output Hi-Z Enable mode
Data Sheet S15865EJ1V0DS
23
PD168111
* Selecting two-phase excitation/microstep driving D8 can be used to select two-phase excitation or microstep driving mode. When D8 = 0, the microstep driving mode is selected. When D8 = 1, the two-phase excitation mode (in which the currents of ch 1 and ch 2 are the same) is selected. The microstep driving mode is selected immediately after reset. When changing the mode from the microstep driving to two-phase excitation, note the following points. If the number of pulses is set to 0 Depending on the setting of D9 that selects the two-phase excitation current, the stop position may differ when the mode is changed. If D9 = "0", excitation is held at an output duty of 100% at the two-phase excitation position of the quadrant of the excitation position after the start point excitation wait has been completed. If D9 = "1", the microstep excitation position is held. If pulse output is started by command setting to set a number of pulses of 1 or more At the first pulse, the operation skips to the two-phase excitation position of the next quadrant and driving is started. If the two-phase excitation mode is selected while the motor is stopped at the one-phase excitation position in the microstep driving mode, it is judged that the position is included in the quadrant in the CW direction, and the motor operates.
(4)
D8 0 1 Operation Mode Microstep driving 2-phase excitation
Microstep stop position (example 2) Microstep stop position (example 1) 2-phase excitation stop position Skipes to the next quadrant
(1)
(3)
(2)
Concept of switching mode from microstep driving to two-phase excitation when pulse is output * Selecting two-phase excitation current D9 is used to select whether the motor is driven at an output duty of 100% (maximum torque operation) or under constant-current control when the two-phase excitation mode is selected. When D9 = "0", the motor is driven at an output duty of 100%. It is excited in two phases and driven at the maximum torque regardless of the set current. When D9 = "1", the motor is excited in two phases at the set motor current. The output current value is controlled to be the same value as the driving current at the phase A = phase B position (position of step 8) in the microstep driving mode.
D9 0 1 Operation Mode Driving at output duty of 100% Driving with constant-current control
24
Data Sheet S15865EJ1V0DS
PD168111
* Selecting MOB output (in microstep driving mode only) The output function of MOB can be selected by Da. When Da = "0", MOB is output once per cycle. When Da = "1", MOB is output four times per cycle. For the output position of MOB, refer to "MOB output position" (set by Db) below.
Da 0 1 MOB Output 1 pulse/cycle 4 pulses/cycle
* MOB output position (in microstep driving mode only) The MOB output timing position can be selected by Db. When Db = "0", MOB is output at the one-phase excitation position (where the current of ch 1 or ch 2 is 100%). When Db = "1", MOB is output at the two-phase excitation position (where the currents of ch 1 and ch 2 are the same). Selection of MOB output (Da) is made in accordance with the setting of Db. When Db = "1", MOB is not output at the reset position.
Db 0 1 MOB Output Position 1-phase excitation position 2-phase excitation position
The output timing of the MOB pin is shown below.
RESET position ch1 current
100 99.5 98.1 95.7 92.4 88.2 83.1 77.3 70.7 63.4 55.6 47.1 38.3 29.0 19.5 9.8 0 --9.8 --19.5 --29.0 --38.3 --47.1 --55.6 --63.4 --70.7 --77.3 --83.1 --88.2 --92.4 --98.1 --95.7 --100 --99.5
0
5
10
15
20
25
30
35
40
45
50
55
60
65
ch2 current
100 99.5 98.1 95.7 92.4 88.2 83.1 77.3 70.7 63.4 55.6 47.1 38.3 29.0 19.5 9.8 0 --9.8 --19.5 --29.0 --38.3 --47.1 --55.6 --63.4 --70.7 --77.3 --83.1 --88.2 --92.4 --98.1 --95.7 --100 --99.5
0
5
10
15
20
25
30
35
40
45
50
55
60
65
MOB output
Da = 0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
MOB output
Da = 1
0
5
10
15
20
25
30
35
40
45
50
55
60
65
MOB Output Timing in Microstep Driving Mode
Data Sheet S15865EJ1V0DS
25
PD168111
Address 3 This register is used to set parameters for acceleration/deceleration control, and the pulse multiplication factor. By setting the parameters for acceleration/deceleration control, the pulse cycle can be gradually changed while the motor is accelerated or decelerated, so that step out of the motor can be prevented. By setting the pulse number multiplication factor to a value other than 1, the number of pulses can be extended in combination with the number of pulses set by the register at address 5. If the default value is not changed, the motor is driven without being accelerated or decelerated, and under the condition that the pulse number multiplication factor is 1. MSB
bit Data Df 0 De 1 Dd 1 Dc Note 1 Db Da D9 D8 D7 D6 D5 D4 D3 Note 2 Note 3 For acceleration/deceleration control
LSB
D2
MSB
D1
LSB
D0
Pulse multiplication factor setting
Notes 1. Reserved 2. Enables/disables acceleration. 3. Enables/disables deceleration. * Pulse number multiplication factor D1 and D0 are used to set the pulse number multiplication factor. By setting a multiplication factor, if the number of motor pulses set by the register at address 5 is insufficient, the number of pulses can be extended maintaining 64 steps/cycle.
D1 0 0 1 1 D0 0 1 0 1 m=2 m=4 Pulse Number Multiplication Factor m m=1
26
Data Sheet S15865EJ1V0DS
PD168111
* Acceleration/deceleration control Seven bits, D2 to D8, are used to set a driving profile for acceleration/deceleration. The pulse rate vs. time draws an S-shaped curve. The shape of this S curve can be changed according to the values set to D2 to D7. An example of acceleration and deceleration operations is illustrated below. 94 pulses each are necessary for acceleration and deceleration. Usually, therefore, set 188 pulses or more (acceleration pulses + deceleration pulses) to perform acceleration and deceleration. If the set number of pulses is less than 94 during acceleration or deceleration, refer to the acceleration/deceleration operation example below.
Pulse rate at constant velacity (address 4)
Pulse rate
Deceleration (= mirror of acceleration)
Pulse width at startup
Acceleration time (Sum of step 1 to 15)
Deceleration time (= acceleration time)
Acceleration pulse number or deceleration pulse number: 94 pulseNote
Note An example of acceleration and deceleration operations is illustrated below. 94 pulses each are necessary for acceleration and deceleration. Usually, therefore, set 188 pulses or more (acceleration pulses + deceleration pulses) to perform acceleration and deceleration. If the set number of pulses is less than 94 during acceleration or deceleration, refer to the acceleration/deceleration operation example below.
Data Sheet S15865EJ1V0DS
27
PD168111
* Parameter for acceleration/deceleration control Reference increment = Pulse cycle (address 4)/Set reference increment Pulse cycle of each step = Pulse cycle (address 4) + Reference increment x Pulse cycle increment table Time of each step = Pulse cycle of each step x Selected data table (number of pulses) Selected Data Table List
STEP Table 1 1 2 3 2 1 1 2 5 4 3 3 2 4 3 4 1 3 4 5 1 2 3 6 1 2 4 7 1 2 3 8 1 2 3 9 1 2 3 10 1 2 3 11 2 4 5 12 3 6 9 13 11 12 13 14 31 17 15 15 31 31 22 STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP
Total: 94 pulses Pulse Cycle Increment Table List
STEP 1 120 STEP 2 56 STEP 3 35 STEP 4 24 STEP 5 18 STEP 6 13 STEP 7 10 STEP 8 8 STEP 9 7 STEP 10 6 STEP 11 5 STEP 12 4 STEP 13 3 STEP 14 2 STEP 15 1
Example: Drive time at each step in the case of Table 1
STEP1 STEP2 STEP3 STEP4 STEP5 STEP6 STEP7 STEP8 STEP9 STEP10 STEP11 STEP12 STEP13 STEP14 STEP15 (Pulse cycle + Reference increment x 120) (Pulse cycle + Reference increment x 56) (Pulse cycle + Reference increment x 35) (Pulse cycle + Reference increment x 24) (Pulse cycle + Reference increment x 18) (Pulse cycle + Reference increment x 13) (Pulse cycle + Reference increment x 10) (Pulse cycle + Reference increment x 8) (Pulse cycle + Reference increment x 7) (Pulse cycle + Reference increment x 6) (Pulse cycle + Reference increment x 5) (Pulse cycle + Reference increment x 4) (Pulse cycle + Reference increment x 3) (Pulse cycle + Reference increment x 2) (Pulse cycle + Reference increment x 1) x2 x5 x2 x1 x1 x1 x1 x1 x1 x1 x2 x3 x11 x31 x31
(The rightmost number indicates the number of pulses when table 1 is used. To use table 2 or 3, refer to Selected Data Table List.) Acceleration time = Deceleration time = Sum of steps 1 to 15
28
Data Sheet S15865EJ1V0DS
PD168111
* Reference increment setting D2 to D4 are used to set a parameter that determines the pulse cycle at each step. The reference increment is the pulse frequency set at address 4 that is divided by the reference increment setting. So that the speed changes draw a typical S-shaped curve, it is recommended to set a value of 8 (1, 0, 0). Reference increment = Pulse cycle (address 4)/Reference increment setting
D4 0 0 0 0 1 1 1 1 D3 0 0 1 1 0 0 1 1 D2 0 1 0 1 0 1 0 32 1 4 8 16 2 Reference Increment Setting
* Table selection This IC approximates the speed change curve during acceleration/deceleration operation to the shape S. The speed change curve can be changed by selecting an internal table. Table 1: S curve with abrupt speed change Table 2: S curve with gentle speed change Table 3: S curve with linear speed change (equivalent to trapezoid waveform)
D6 0 0 1 1 D5 0 Table 1 1 0 1 Table 2 Table 3 Table Selection
* Start time setting D8 and D7 are used to select the operation time multiplication factor during an acceleration/deceleration operation. The number of pulses necessary for each step during acceleration/deceleration can be selected from x1, x2, and x4. For the number of pulses at each step, refer to Selected Data Table List.
Number of Pulses Necessary for Acceleration or Deceleration 94 188 376
D8 0 0 1 1
D7 0
Start Time Setting
x1 1 0 1 x2 x4
Data Sheet S15865EJ1V0DS
29
PD168111
* Enabling/disabling acceleration An acceleration operation can be performed in accordance with the acceleration control setting. The acceleration function can be enabled or disabled by Da. * Enabling/disabling deceleration A deceleration operation can be performed in accordance with the deceleration control setting. The deceleration function can be enabled or disabled by D9.
Operation Mode Da 0 1 0 1 D9 Acceleration 0 0 1 1 Disabled Enabled Disabled Enabled Deceleration Disabled Disabled Enabled Enabled
30
Data Sheet S15865EJ1V0DS
PD168111
Example of acceleration/deceleration operation
(1) Acceleration enabled/ deceleration enabled
Pulses/s Pulses/s
(1') Acceleration enabled/ deceleration enabled
Set pulses Acceleration/ deceleration pulses
Set pulses Condition: Set pulses/2 (2) Acceleration enabled/ deceleration disabled
Pulses/s Pulses/s
(2') Acceleration enabled/ deceleration enabled
Condition: Set pulses Pulses/s
(3) Acceleration disabled/ deceleration enabled
Pulses/s Pulses/s
(4') Acceleration disabled/ deceleration enabled
Condition: Set pulses The uppermost left figure shows the ideal operation waveform. If the number of set pulses is less than the number of acceleration/deceleration control pulses, the operation is performed as illustrated by the figure at the uppermost right. (1') The deceleration operation is started when 1/2 of the set number of pulses has been reached during the acceleration operation. Therefore, acceleration and deceleration are always mirrored. (2') If the set number of pulses is less than the number of acceleration/deceleration control pulses during only the acceleration operation, the operation is stopped at the pulse rate in the middle of acceleration. (4') If the set number of pulses is less than the number of acceleration/deceleration control pulses during only the deceleration operation, the last pulse rate does not reach the target value. The set number of pulses is output in accordance with the deceleration pulse curve, and the operation is stopped.
Data Sheet S15865EJ1V0DS
31
PD168111
Address 4 This register is used to set the pulse cycle per step (64 steps/cycle). MSB bit Data Df 1 De 0 Dd 0 Dc Db Da D9 D8 D7 D6 D5 D4 D3 D2 D1 Pulse cycle LSB D0
* Pulse cycle Thirteen bits, D0 to Dc, are used to set the pulse cycle per step. The pulse cycle can be set in a range of 0 to 8191 s at a resolution of 1.0 s. If all the 13 bits are "0", no pulse is output and the driving status is maintained. Example of setting pulse cycle
Dc......D0 0000000000000 0000000000001 0000000000010 : 1111111111101 1111111111110 1111111111111 Set Value (s) 0 1.0 2.0 : 8189 8190 8191
32
Data Sheet S15865EJ1V0DS
PD168111
Address 5 This register is used to set the number of pulses. The actual number of pulses is set by the product of the pulse number multiplication factor and the number of pulses set at address 3. MSB
bit Data Df 1 De 0 Dd 1 Dc Db Da D9 D8 D7 D6 D5 D4 D3 D2 D1
LSB
D0
Number of pulses
* Number of pulses Set the number of pulses to drive the motor. D0 to Dc are used to set pulses in a range of 0 to 8191 pulses. If the pulse number multiplication factor is set to a value other than 1 by the register at address 3, the number of pulses set here is multiplied by the set multiplication factor (m) of address 3. The number of pulses is internally multiplied by m and then counted. If it is set to output pulses to EXT0, the number of counts output is the set value itself (0 to 8191 x m). Example of setting number of pulses Dc......D0 0000000000000 0000000000001 0000000000010 : 1111111111101 1111111111110 1111111111111 Set Value 0 m 2xm : 8189 x m 8190 x m 8191 x m
m indicates the set value of the pulse number multiplication factor of address 3. If the value of the 13 bits D0 to Dc is "0", the pulse is not output and the driving status is maintained.
Data Sheet S15865EJ1V0DS
33
PD168111
ABSOLUTE MAXIMUM RATINGS (TA = 25C: GLASS EPOXY BOARD OF 100 mm x 100 mm x 1 mm WITH COPPER FOIL AREA OF 15%)
Parameter Power supply voltage Symbol VDD VM Input voltage Output pin voltage DC output current Instantaneous output current Power consumption Peak junction temperature Storage temperature VIN VOUT ID(DC) ID(pulse) PT TCH(MAX) Tstg DC PW < 10 ms, Duty 20% Conditions Control block Motor block Rating -0.5 to +6.0 -0.5 to +6.0 -0.5 to VDD+0.5 6.2 0.4 0.7 0.7 150 -55 to +150 V V A/ch A/ch W C C Unit V
RECOMMENDED OPERATING CONDITIONS (TA = 25C: GLASS EPOXY BOARD OF 100 mm x 100 mm x 1 mm WITH COPPER FOIL AREA OF 15%)
Parameter Power supply voltage Symbol VDD VM Input voltage DC output current Instantaneous output current External CLK input frequency SCLK input frequency LATCH-SCLK time SDATA setup time SDATA hold time EXT pin output drive current MOB pin output sink current Operating temperature range Peak junction temperature VIN ID(DC) ID(pulse) OSCIN fCLK tL-S tSETUP tHOLD IEXT IMOB TA TCH(MAX) Buffer output Open-drain output -10 200 80 80 -5 5 5 75 150 DC PW < 10 ms, Duty 20% Conditions Control block Motor block MIN. 2.7 2.7 0 -0.35 -0.6 4 5 TYP. MAX. 3.6 5.5 VDD +0.35 +0.6 6.2 6 Unit V V V A/ch A/ch MHz MHz ns ns ns mA mA C C
Serial Command Timing Chart
Setup time = 80 ns MIN. Hold time = 80 ns MIN.
LATCH
SCLK
SDATA
LATCH - SCLK time = min 200 ns
34
Data Sheet S15865EJ1V0DS
PD168111
ELECTRICAL CHARACTERISTICS (UNLESS OTHERWISE SPECIFIED, VDD = VM = 3 V, TA = 25C)
Parameter VDD pin current after reset VDD pin current in standby mode VDD pin current during operation VM leakage current High-level input current Low-level input current High-level input voltage Low-level input voltage Input hysteresis voltage H bridge on-resistance Output turn-on time Output turn-off time EXT high-level output voltage EXT low-level output voltage EVRMAX voltage Symbol IDD(STB) IDD(STB2) IDD(STB3) IDD(ACT) IM(OFF) IIH IIL VIH VIL Vhys RON tON tOFF VextH VextL EVRMAX IO = -100 A IO = +100 A Address 2 (D0 to D4) = (1, 1, 1, 1, 1) 450 500 0.9 x VDD 0.1 x VDD 550 Per VM pin, VM = 5.5 V, in standby mode VIN = VDD VIN = 0 SCLK,SDATA,LATCH,RESETB, EN,OSCin pins SCLK,SDATA,LATCH,RESETB, EN,OSCin pins SCLK,SDATA,LATCH,RESETB, EN,OSCin pins IM = 0.35 A, sum of upper and lower stages RM = 20 0.3 2.0 0.5 0.5 -1.0 0.7 x VDD 0.3 x VDD Conditions External CLK (OSCin) stopped External CLK (OSCin) stopped External CLK (OSCin) input MIN. TYP. MAX. 1.0 30 300 3.0 1.0 1.0 Unit
A A A
mA
A A A
V V V
s s
V V mV
Cautions 1. Undervoltage lockout circuit (UVLO) operates at 1.7 V TYP. and the output goes into a Hi-Z state. Internal data such as address settings is initialized. The UVLO circuit does not operate during reset. 2. The motor current accuracy varies depending on the motor actually used. With this IC, the total of the reference voltage EVRMAX error and the current sense circuit error is within 10%.
Data Sheet S15865EJ1V0DS
35
PD168111
PACKAGE DRAWING
24-PIN PLASTIC TSSOP (5.72 mm (225))
24 13 detail of lead end F G R
P
L S
1
12
E
A A' S
H I J
C D M
M
K B
N
S
NOTE Each lead centerline is located within 0.10 mm of its true position (T.P.) at maximum material condition.
ITEM A A' B C D E F G H I J K L M N P R S
MILLIMETERS 6.650.10 6.50.1 0.575 0.5 (T.P.) 0.220.05 0.10.05 1.2 MAX. 1.00.05 6.40.1 4.40.1 1.00.1 0.170.025 0.5 0.10 0.08 3+5 -3 0.25 0.60.15 P24MA-50-6A5
36
Data Sheet S15865EJ1V0DS
PD168111
RECOMMENDED SOLDERING CONDITIONS
The PD168111 should be soldered and mounted under the following recommended conditions. For soldering methods and conditions other than those recommended below, contact an NEC Electronics sales representative. For technical information, see the following website. Semiconductor Device Mount Manual (http://www.necel.com/pkg/en/mount/index.html) Recommended Soldering Conditions for Surface Mounting Type
PD168111MA-6A5: 24-pin plastic TSSOP (5.72 mm (225))
Recommended Condition Symbol IR60-00-3
Soldering Method
Soldering Conditions
Infrared reflow
Package peak temperature: 260C, Time: 60 seconds max. (at 220C or higher), Count: Three times or less, Exposure limit: None, Flux: Rosin flux with low chlorine (0.2 Wt% or below) recommended
Caution Do not use different soldering methods together (except for partial heating).
Data Sheet S15865EJ1V0DS
37
PD168111
[MEMO]
38
Data Sheet S15865EJ1V0DS
PD168111
NOTES FOR CMOS DEVICES
1 PRECAUTION AGAINST ESD FOR SEMICONDUCTORS Note: Strong electric field, when exposed to a MOS device, can cause destruction of the gate oxide and ultimately degrade the device operation. Steps must be taken to stop generation of static electricity as much as possible, and quickly dissipate it once, when it has occurred. Environmental control must be adequate. When it is dry, humidifier should be used. It is recommended to avoid using insulators that easily build static electricity. Semiconductor devices must be stored and transported in an anti-static container, static shielding bag or conductive material. All test and measurement tools including work bench and floor should be grounded. The operator should be grounded using wrist strap. Semiconductor devices must not be touched with bare hands. Similar precautions need to be taken for PW boards with semiconductor devices on it. 2 HANDLING OF UNUSED INPUT PINS FOR CMOS Note: No connection for CMOS device inputs can be cause of malfunction. If no connection is provided to the input pins, it is possible that an internal input level may be generated due to noise, etc., hence causing malfunction. CMOS devices behave differently than Bipolar or NMOS devices. Input levels of CMOS devices must be fixed high or low by using a pull-up or pull-down circuitry. Each unused pin should be connected to VDD or GND with a resistor, if it is considered to have a possibility of being an output pin. All handling related to the unused pins must be judged device by device and related specifications governing the devices. 3 STATUS BEFORE INITIALIZATION OF MOS DEVICES Note: Power-on does not necessarily define initial status of MOS device. Production process of MOS does not define the initial operation status of the device. Immediately after the power source is turned ON, the devices with reset function have not yet been initialized. Hence, power-on does not guarantee out-pin levels, I/O settings or contents of registers. Device is not initialized until the reset signal is received. Reset operation must be executed immediately after power-on for devices having reset function.
Data Sheet S15865EJ1V0DS
39


▲Up To Search▲   

 
Price & Availability of UPD168111

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X